Fronius Error codes

Fronius Error codes

This list of Fronius Error codes may not be complete.  We are adding codes as we learn about them.

Error Code Message

STATE 101 Grid voltage beyond permitted limits

STATE 105 Grid frequency is too high

STATE 107 Synchronisation with the public mains supply not possible

STATE 108 Islanding detected


STATE 201 Grid voltage beyond permitted limits

STATE 202 Grid voltage is lower than the specified limit

STATE 203 Grid frequency is higher than the specified limit

STATE 204 Grid frequency is lower than the specified limit

STATE 205 Change of public mains impedance

STATE 206 Absolute value of the impedance is too high

STATE 207 Mains relay does not open in spite of switch off signal

STATE 208 Mains relay does not close in spite of switch on signal


STATE 301 Safety circuit detects a current peak on the PV generator side

STATE 303 Heat sink temperature on the DC-AC board is too high

STATE 304 Heat sink temperature on the DC-DC board is too high

STATE 305 Feed-in process not possible, even though public mains parameter within the limits

STATE 306 POWER LOW

STATE 307 DC LOW

STATE 308 Intermediate circuit voltage out of the maximum limit


STATE 401 Communication error between IG control and the DC-DC board

STATE 402 Write access to the internal Fronius IG memory failed

STATE 403 The area in the internal memory for the country setting is incomplete

STATE 404 Connection between the control unit and the ENS is faulty

STATE 405 An old or incorrect version of the ENS microprocessors has been recognised

STATE 406 Temperature sensor on the DC-AC board faulty or not connected

STATE 407 Temperature sensor on the DC-DC board faulty or not connected

STATE 408 Unsymmetry on the public mains detected

STATE 409 Supply of the DC-AC board not available

STATE 410 Service plug on the DC-AC board is not set correctly

STATE 412 Value for fixed voltage is set higher than the open circuit voltage of the PV generator

STATE 413 Open circuit voltage too high in the moment of transformer switching

STATE 414 Memory array for Fronius IG type in EE-PROM faulty

STATE 415 No END-enabling signal despite release by IG-control

STATE 416 Communication error between IG-Control and power stack

STATE 417 Hardware ID-collision

STATE 419 Two or more power stacks with identical Unique ID

STATE 420 Incomplete number of power stacks detected after reaching online threshold according to device type

STATE 421 Hardware ID sequence error

STATE 425 Receive time-out for data exchange with one or more power stacks exceeded

STATE 431 All power stacks are in boot mode

STATE 432 Consistent error in power stack management

STATE 433 Allocation error of dynamic addresses

STATE 434 Allocation error of dynamic addresses

STATE 434 Ground fault detected

STATE 435 Wrong configuration for EE-Prom

STATE 436 Error transmission faulty

STATE 437 Power stack work around is active

STATE 438 Error during state code transmission

STATE 441 Power rack fan faulty

STATE 442 Master for one phase could not be assigned

STATE 443 DC-DC energy transfer failure.

STATE 444 AC monitoring self test interrupted

STATE 475    Inverter detected a ground fault - Possible moisture issue

STATE 501 Heat sink temperature too high, although Fronius IG is on low output

STATE 504 An isolation fault between DC+ or DC- to earth has been detected

STATE 505 The area in the internal memory for the “Setup” values is incomplete

STATE 506 The area in the internal memory for the “Total” values is incomplete

STATE 507 The area in the internal memory for the “Day/Year” values is incomplete

STATE 508 The area in the internal memory for the “WR number” is damaged

STATE 509 No feed in operation for 24 hours

STATE 510 Errors detected by LocalNet self diagnostic system

STATE 511 Errors detected by LocalNet Sensor Card self diagnostic system

STATE 512 According to the device type too many power stacks have been detected

STATE 513 Power stacks in boot mode

STATE 514 Incomplete number of power stacks detected after reaching online threshold – Device type

STATE 515 One or more power stacks notified STATE 406/ 407/ 409/ 410

STATE 516 One power stack exceeds the permitted limit of error messages per day (>50x)

STATE 517 Permanent POWER LOW or DC LOW error

STATE 993 Reporting Error
STATE 996 Communication error between Fronius Datalogger and Solar.web

    • Related Articles

    • Sungrow Crystal Error Codes

      Please download the linked file to learn more about the Sungrow Crystal Error Codes https://tdrive.li/474jpB
    • Sungrow SH5K error codes

      Please download this file for detailed information on Sungrow Error Codes for the Hybrid SH5K inverter. https://tdrive.li/YmYfSF
    • Fronius WiFi monitoring Setup

      Please find our attached our setup guide for the Fronius WiFi monitoring app.  Please feel free to call between 9am and 5pm Monday to Friday if you need assistance, alternatively, you can respond to this email with your questions. Fronius - Solarweb ...
    • Fronius Solarweb App - consumer training

      TRAINING OVERVIEW This article covers education on the following topics: - Why is solar monitoring important - Understanding the solarweb pro apps - Solarweb Pro - without a smart meter - Solarweb Pro - without a smart meter - Consumption monitoring ...
    • Sungrow - iSolarcloud - share with GI Energy

      Share your system monitoring with GI Energy Sharing your solar monitoring with GI Energy means that when you have questions or issues, we can quickly access your monitoring to respond and diagnose any issues.  To do this, you'll need to enter our ...